0466002.NR
Littelfuse Inc.
- Lifecycle
- Active
- Stock
- 2802 PCS
- Package
- 1206 (3216 Metric)
- Series
- Fuses
Esta comparação detalhada entre 0466002.NR e 0466002.NRHF fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.
Replacement verdict
The 0466002.NRHF is a RoHS-compliant, halogen-free variant of the 0466002.NR fuse, sharing identical electrical and dimensional characteristics. It is a direct functional replacement candidate, with the primary distinction being environmental compliance rather than performance.
Littelfuse Inc.
Littelfuse Inc.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | 0466002.NRHF | 0466002.NR | Why it matters |
|---|---|---|---|
| Series | 466 | 466 | Confirms both fuses belong to the same Littelfuse 466 series, ensuring physical and electrical compatibility. |
| Current Rating | 2 A | 2 A | The hold current determines the maximum continuous current the fuse can carry without opening. |
| Voltage Rating | 32 VAC / 32 VDC | 32 VAC / 32 VDC | The voltage rating must meet or exceed the circuit voltage to ensure safe interruption of fault currents. |
| Interrupting Rating | 50 A | 50 A | Defines the maximum fault current the fuse can safely break without damage or hazard. |
| Nominal Cold Resistance | 0.0285 Ohms | 0.0285 Ohms | Low resistance minimizes voltage drop and power loss in the protected circuit. |
| Nominal Melting I²t | 0.5 A²s | 0.5 A²s | I²t determines the energy required to open the fuse, critical for coordinating with inrush currents and other protection devices. |
| Operating Temperature Range | -55°C to +90°C | -55°C to +90°C | Ensures the fuse performs reliably across the application's environmental temperature extremes. |
| Mounting Type | Surface Mount | Surface Mount | Both are surface-mount devices, but the HF suffix indicates a halogen-free, RoHS-compliant construction. |
| Halogen-Free / RoHS | Yes (Halogen-Free, RoHS) | RoHS | The HF variant meets stricter halogen-free requirements, which matters for environmental compliance and certain industrial applications. |
| Package / Size | 1206 (3216 Metric) | 1206 (3216 Metric) | Identical footprint ensures either part can be placed on the same PCB pad layout. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | 0466002.NR | 0466002.NRHF |
|---|---|---|
| Series | SlimLine™ 466 | SlimLine™ 466 |
| Part Status | Active | Active |
| Mounting Type | Surface Mount | Surface Mount |
| Fuse Type | Board Mount (Cartridge Style Excluded) | Board Mount (Cartridge Style Excluded) |
| Current Rating (Amps) | 2 A | 2 A |
| Voltage Rating - AC | 63 V | 63 V |
| Voltage Rating - DC | 63 V | 63 V |
| Response Time | Fast Blow | Fast Blow |
| Breaking Capacity @ Rated Voltage | 50A | 50A |
| Melting I²t | 0.2326 | 0.2326 |
| Approval Agency | CSA, UL | CSA, UL |
| Operating Temperature | -55°C ~ 90°C | -55°C ~ 90°C |
The 0466002.NRHF and 0466002.NR are both surface-mount fuses from Littelfuse's 466 series. The primary difference is the "HF" suffix on 0466002.NRHF, which indicates the part is halogen-free and RoHS-compliant. The 0466002.NR is the standard version. Both share the same electrical ratings, including a 2 A current rating and 32 V AC/DC voltage rating, but the HF variant meets additional environmental compliance requirements.
Yes, both fuses have identical electrical specifications: 2 A rated current, 32 V AC/DC rated voltage, and the same breaking capacity. They are electrically interchangeable in circuits designed for the 466 series 2 A fuse. However, substitution should be validated against the specific application requirements and manufacturer documentation.
Yes, both parts are in the same 1206 (3216 metric) surface-mount package. They share identical footprint dimensions and PCB land patterns, allowing them to be used interchangeably without layout changes.
The "HF" suffix indicates that the 0466002.NRHF is a halogen-free version of the fuse. This means it does not contain halogenated flame retardants and meets specific environmental and safety requirements, often preferred for applications requiring low toxicity and reduced environmental impact.
Yes, both the 0466002.NRHF and 0466002.NR are RoHS compliant. However, the 0466002.NRHF additionally meets halogen-free requirements, which may be necessary for certain applications or markets with stricter environmental regulations.
Yes, the 0466002.NRHF can be used as a direct drop-in replacement for the 0466002.NR in most applications because they share the same package, electrical ratings, and performance characteristics. The only difference is the halogen-free construction of the HF version, which does not affect form, fit, or function.
Both fuses are typically used for overcurrent protection in a wide range of electronic devices, including consumer electronics, industrial equipment, and telecommunications systems. They are suitable for applications requiring a compact surface-mount fuse with a 2 A rating and 32 V AC/DC capability.
No, both the 0466002.NRHF and 0466002.NR have the same breaking capacity rating as specified in the Littelfuse 466 series datasheet. The breaking capacity is identical because the internal fuse element and construction are the same, with only the halogen content differing.