ACS724LLCTR-20AU-T vs ACS723LLCTR-05AB-T

Esta comparação detalhada entre ACS724LLCTR-20AU-T e ACS723LLCTR-05AB-T fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ACS724LLCTR-20AU-T is not a direct drop-in replacement for the ACS723LLCTR-05AB-T due to differences in current sensing range, output type, and package construction, but it can serve as a functional substitute in applications where a higher current range and unidirectional sensing are acceptable. Design validation is required to confirm compatibility with the target circuit.

Current Sensing Range Validation required
Output Type Not compatible
Package Type Validation required
Supply Voltage High match

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ACS723LLCTR-05AB-T ACS724LLCTR-20AU-T Why it matters
Current Sensing Range ±5 A ±20 A Defines the maximum measurable current; a ±20 A sensor cannot be directly substituted where ±5 A full-scale resolution is required, and vice versa.
Sensitivity 400 mV/A 100 mV/A Determines the output voltage swing per amp; different sensitivity changes the ADC scaling and effective resolution in the application circuit.
Output Type Analog, bidirectional Analog, unidirectional Bidirectional parts measure both positive and negative current, while unidirectional parts only measure one polarity, affecting circuit topology and signal conditioning.
Supply Voltage 4.5 V to 5.5 V 4.5 V to 5.5 V Both operate from a 5 V rail, so power supply compatibility is maintained between the two devices.
Isolation Voltage 2.1 kVrms 2.1 kVrms Rated isolation between the current path and signal side; identical ratings mean safety and creepage requirements are equivalent.
Bandwidth 80 kHz 120 kHz Higher bandwidth allows faster current transient tracking; a mismatch can affect control loop response in motor or power conversion designs.
Package 8-lead SOIC 8-lead SOIC Identical footprint and pinout enable drop-in PCB compatibility without layout changes.
Operating Temperature Range -40 °C to 150 °C -40 °C to 150 °C Matching temperature ratings ensure both parts are suitable for the same industrial and automotive thermal environments.
Typical Accuracy ±3% ±1.5% Accuracy affects measurement error budget; the ACS724 offers tighter accuracy, which may be required for precision current monitoring.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ACS724LLCTR-20AU-T ACS723LLCTR-05AB-T
Part Status Active Active
For Measuring DC AC/DC
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop
Current - Sensing 20A 5A
Number of Channels 1 1
Output Ratiometric, Voltage Ratiometric, Voltage
Sensitivity 200mv/A 400mV/A
Frequency 120kHz DC ~ 80kHz
Linearity ±1.5% ±1%
Accuracy ±0.7% ±3%
Voltage - Supply 4.5V ~ 5.5V 5V
Response Time 4µs 5µs
Current - Supply (Max) 14mA 14mA
Operating Temperature -40°C ~ 150°C -40°C ~ 150°C
Polarization Unidirectional Bidirectional
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the primary differences between the ACS723LLCTR-05AB-T and the ACS724LLCTR-20AU-T?

The ACS723LLCTR-05AB-T is a bidirectional, 5 A full-scale current sensor with an analog output, while the ACS724LLCTR-20AU-T is a unidirectional, 20 A full-scale current sensor with an analog output. They differ in measurement range, directionality, and sensitivity.

Are the ACS723LLCTR-05AB-T and ACS724LLCTR-20AU-T pin-to-pin compatible?

Yes. Both devices are offered in the same SOIC-8 package with the same pinout, allowing for a common PCB footprint. However, external component values and firmware thresholds may need adjustment due to different sensitivities and measurement ranges.

What is the sensitivity of each device?

The ACS723LLCTR-05AB-T has a typical sensitivity of 400 mV/A. The ACS724LLCTR-20AU-T has a typical sensitivity of 200 mV/A. These values are specified in the respective manufacturer datasheets.

Can the ACS724LLCTR-20AU-T measure bidirectional current like the ACS723LLCTR-05AB-T?

No. The ACS724LLCTR-20AU-T is a unidirectional sensor designed to measure current in one direction only. The ACS723LLCTR-05AB-T is bidirectional and can measure current flowing in both directions.

What is the supply voltage range for both devices?

Both the ACS723LLCTR-05AB-T and ACS724LLCTR-20AU-T operate from a single 5 V supply. The typical supply voltage is 5.0 V, with an operating range specified in the datasheets.

What is the isolation voltage rating for these current sensors?

Both devices provide basic isolation with a rated isolation voltage of 2.1 kV RMS for 1 minute, as specified in the Allegro MicroSystems datasheets. This allows high-side current sensing in applications requiring galvanic isolation.

Which device is better for low-current measurement accuracy?

The ACS723LLCTR-05AB-T is better suited for low-current measurement because its 5 A full-scale range and 400 mV/A sensitivity provide higher resolution for small currents compared to the ACS724LLCTR-20AU-T, which has a 20 A range and 200 mV/A sensitivity.

Do both devices have the same operating temperature range?

Yes. Both the ACS723LLCTR-05AB-T and ACS724LLCTR-20AU-T are specified for an operating temperature range of -40 °C to 125 °C, as stated in their respective datasheets.