Esta comparação detalhada entre ADF4001BCPZ e ADF4002BCPZ-RL7 fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADF4001BCPZ is a functional replacement candidate for the ADF4002BCPZ-RL7 in PLL synthesizer applications, sharing the same 20-lead LFCSP package, supply voltage range, and 3-wire serial interface, though the designer must validate the differing maximum operating frequency, phase detector frequency, and reference input requirements against the target design.

Package Type High match
Supply Voltage Range High match
Maximum Operating Frequency Validation required
Phase Detector Frequency Validation required

Parts at a glance

Part A

ADF4001BCPZ

Analog Devices Inc.

Lifecycle
Active
Stock
1703 PCS
Package
WFQFN-20
Series
Horário - Geradores de relógios, PLLs, Sintetizadores de Frequências
Part B

ADF4002BCPZ-RL7

Analog Devices Inc.

Lifecycle
Active
Stock
7422 PCS
Package
WFQFN-20
Series
Horário - Geradores de relógios, PLLs, Sintetizadores de Frequências

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADF4002BCPZ-RL7 ADF4001BCPZ Why it matters
Maximum RF Input Frequency 400 MHz 200 MHz Determines the highest reference or feedback frequency the PLL can accept; the ADF4002 supports twice the input frequency of the ADF4001.
Number of Programmable Counters Dual (R and N counters) Single (N counter only) The ADF4002 includes both reference (R) and feedback (N) counters, enabling full fractional-N style flexibility, while the ADF4001 has only an N counter.
Phase Detector Frequency Up to 104 MHz Up to 55 MHz Higher phase detector frequency allows wider loop bandwidth and faster lock times; the ADF4002 supports nearly double the ADF4001's PFD rate.
Supply Voltage Range 2.7 V to 3.3 V 2.7 V to 5.5 V The ADF4001 tolerates a wider supply range including 5 V systems, while the ADF4002 is limited to 3.3 V maximum.
Package 20-Lead LFCSP 20-Lead LFCSP Both use the same 20-lead LFCSP footprint, but the ADF4002 variant is supplied in tape-and-reel (RL7) packaging for automated assembly.
Operating Temperature Range -40 °C to +85 °C -40 °C to +85 °C Identical industrial temperature range means both parts are interchangeable in the same thermal environments.
Charge Pump Current (Programmable) Up to 5 mA Up to 5 mA Matching charge pump current ranges allow similar loop filter design and comparable phase noise performance.
Interface 3-wire serial (SPI-compatible) 3-wire serial (SPI-compatible) Both use the same serial programming interface, simplifying firmware reuse when substituting one for the other.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADF4001BCPZ ADF4002BCPZ-RL7
Part Status Active Active
Type Clock Generator (RF) Clock/Frequency Synthesizer (RF), Phase Detector
PLL Yes Yes with Bypass
Input CMOS, TTL CMOS, TTL
Output Clock Clock
Number of Circuits 1 1
Ratio - Input: Output 2:1 2:1
Differential - Input: Output Yes/No Yes/No
Frequency - Max 200MHz 400MHz
Divider / Multiplier Yes/No Yes/No
Voltage - Supply 2.7V ~ 5.5V 2.7V ~ 3.3V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the ADF4002BCPZ-RL7 and the ADF4001BCPZ?

The ADF4002BCPZ-RL7 is a 400 MHz PLL frequency synthesizer with an integrated phase detector and programmable charge pump, while the ADF4001BCPZ is a 200 MHz PLL frequency synthesizer with similar architecture but lower maximum operating frequency. Both are offered in 20-lead LFCSP packages, but the ADF4002 supports higher reference and RF input frequencies and includes a programmable dual-modulus prescaler, whereas the ADF4001 is limited to lower frequency operation.

Are the ADF4002BCPZ-RL7 and ADF4001BCPZ pin-compatible?

Both devices are packaged in a 20-lead LFCSP (CP-20-1) with the same pin count and footprint, but pin functions and internal register maps differ. The ADF4002 and ADF4001 are not drop-in replacements; the PCB layout may be shared, but the surrounding circuitry and software configuration must be redesigned for each part.

What is the maximum RF input frequency for each device?

The ADF4002BCPZ-RL7 supports RF input frequencies up to 400 MHz, while the ADF4001BCPZ supports RF input frequencies up to 200 MHz. The reference input frequency for both devices is specified up to 100 MHz.

Do both parts use the same serial interface for programming?

Yes, both the ADF4002BCPZ-RL7 and ADF4001BCPZ use a 3-wire serial interface (CLK, DATA, LE) for programming the internal registers. However, the register maps and bit definitions differ between the two devices, so firmware written for one part cannot be used directly with the other without modification.

What are the supply voltage and power consumption specifications?

Both the ADF4002BCPZ-RL7 and ADF4001BCPZ operate from a 3.0 V to 3.6 V supply. The ADF4002 typically draws about 7 mA, while the ADF4001 typically draws about 5 mA, depending on the programmed charge pump current and operating conditions.

Can the ADF4001BCPZ be used as a direct replacement for the ADF4002BCPZ-RL7 in an existing design?

No. Although both are 20-lead LFCSP PLL synthesizers, the ADF4001BCPZ has a lower maximum RF input frequency (200 MHz vs. 400 MHz) and a different register map. A direct substitution would require verifying that the system's RF frequency, loop filter design, and software configuration are compatible with the ADF4001 specifications.

What is the difference in phase detector frequency and charge pump current between the two parts?

Both devices feature a programmable phase detector and charge pump. The ADF4002BCPZ-RL7 offers a maximum phase detector frequency of 100 MHz, while the ADF4001BCPZ is specified for a maximum phase detector frequency of 55 MHz. Charge pump current is programmable in both devices, but the available current settings and register encoding differ.