ADF4001BRUZ
Analog Devices Inc.
- Lifecycle
- Active
- Stock
- 6578 PCS
- Package
- TSSOP-16
- Series
- Horário - Geradores de relógios, PLLs, Sintetizadores de Frequências
Esta comparação detalhada entre ADF4001BRUZ e ADF4002BRUZ fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.
Replacement verdict
The ADF4001BRUZ is a functional replacement candidate for the ADF4002BRUZ in many PLL synthesizer designs, since both share the same TSSOP-16 footprint, 3 V to 3.6 V supply range, and three-wire serial control interface. However, the ADF4002BRUZ integrates an on-chip phase detector with programmable charge pump and anti-backlash pulse width, while the ADF4001BRUZ relies on an external phase-frequency detector and charge pump, so the surrounding loop filter and reference circuitry must be revalidated before substitution.
Analog Devices Inc.
Analog Devices Inc.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADF4002BRUZ | ADF4001BRUZ | Why it matters |
|---|---|---|---|
| Number of RF Inputs | 2 (dual) | 1 (single) | The ADF4002 has two RF inputs allowing it to drive two separate VCOs or switch between frequencies, while the ADF4001 has only one RF input, limiting it to a single signal path. |
| Maximum RF Input Frequency | 400 MHz | 200 MHz | The higher maximum input frequency of the ADF4002 supports higher-frequency PLL designs, whereas the ADF4001 is limited to lower-frequency applications. |
| Phase Detector Frequency | Up to 104 MHz | Up to 55 MHz | A higher phase detector frequency enables wider loop bandwidths and faster lock times; the ADF4002 supports roughly double the phase detector rate of the ADF4001. |
| Programmable Charge Pump Current | 0.3 mA to 5 mA | 0.3 mA to 5 mA | Charge pump current range affects loop filter design and loop dynamics; both devices offer the same programmable range, so this is not a differentiator. |
| Supply Voltage Range | 2.7 V to 3.3 V | 2.7 V to 3.3 V | Both parts operate over the same supply range, so power supply design is interchangeable between them. |
| Package | 16-Lead TSSOP | 16-Lead TSSOP | Identical package and pin count simplify board-level substitution, though pin functions may differ and must be verified. |
| Operating Temperature Range | -40°C to +85°C | -40°C to +85°C | Matching industrial temperature ranges mean both parts suit the same environmental conditions. |
| Digital Interface | 3-wire serial (SPI-compatible) | 3-wire serial (SPI-compatible) | Both use the same serial programming interface, so firmware/software control logic is largely reusable across the two parts. |
| Prescaler | Dual-modulus 8/9, 16/17, 32/33, 64/65 | Dual-modulus 8/9, 16/17, 32/33, 64/65 | Identical prescaler options give the same frequency synthesis flexibility, so this parameter does not distinguish the parts. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADF4001BRUZ | ADF4002BRUZ |
|---|---|---|
| Part Status | Active | Active |
| Type | Clock Generator (RF) | Clock/Frequency Synthesizer (RF), Phase Detector |
| PLL | Yes | Yes with Bypass |
| Input | CMOS, TTL | CMOS, TTL |
| Output | Clock | Clock |
| Number of Circuits | 1 | 1 |
| Ratio - Input: Output | 2:1 | 2:1 |
| Differential - Input: Output | Yes/No | Yes/No |
| Frequency - Max | 200MHz | 400MHz |
| Divider / Multiplier | Yes/No | Yes/No |
| Voltage - Supply | 2.7V ~ 5.5V | 2.7V ~ 3.3V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
Both are PLL frequency synthesizers, but the ADF4002BRUZ integrates a phase frequency detector (PFD) with programmable charge pump and a 14-bit reference counter plus a 13-bit N counter, while the ADF4001BRUZ provides a 14-bit reference counter and a 13-bit N counter with a phase detector but no integrated charge pump, requiring an external loop filter amplifier/charge pump configuration. The ADF4002BRUZ is specified for RF bandwidth up to 400 MHz, whereas the ADF4001BRUZ is specified for operation up to 200 MHz.
Both devices are offered in a 16-lead TSSOP (RUZ suffix), but pin functions differ: the ADF4002BRUZ includes charge pump output and related pins that the ADF4001BRUZ does not provide in the same configuration. Therefore, they are not directly pin-for-pin interchangeable without verifying the pinout against the respective datasheets.
The ADF4002BRUZ is specified for RF input frequencies up to 400 MHz. The ADF4001BRUZ is specified for RF input frequencies up to 200 MHz. Designs requiring operation above 200 MHz should use the ADF4002BRUZ.
Both use a 3-wire serial interface (CLK, DATA, LE) and are programmed via 24-bit registers. However, the register bit definitions and available functions differ because the ADF4002BRUZ includes charge pump current and phase detector polarity settings not present in the ADF4001BRUZ. Firmware written for one device cannot be assumed to work unchanged on the other.
Both devices operate from a 2.7 V to 3.3 V supply, with a nominal 3.0 V or 3.3 V rail. The digital interface and analog sections share this supply range per the manufacturer datasheets.
The ADF4002BRUZ is the appropriate choice because it integrates a programmable charge pump, eliminating the need for an external charge pump stage. The ADF4001BRUZ does not include an integrated charge pump and requires external circuitry for loop filter drive.
Both devices are specified for the industrial temperature range of −40 °C to +85 °C in the RUZ (TSSOP) package, per the manufacturer datasheets.