ADM706ARZ vs ADM706PAR

Esta comparação detalhada entre ADM706ARZ e ADM706PAR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADM706ARZ and ADM706PAR are functionally compatible microprocessor supervisory circuits sharing the same package, pinout, and core reset functionality, making them viable substitutes in most designs. The primary distinction lies in their reset threshold voltage, which must be validated against the specific supply rail of the target application before substitution.

Package Type High match
Pin Configuration High match
Reset Threshold Voltage Validation required
Supply Voltage Range High match

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADM706ARZ ADM706PAR Why it matters
Reset Threshold Voltage (typ) 4.65 V 2.63 V Determines the supply voltage level at which the supervisor asserts reset; the two parts monitor different nominal rails (5 V vs 3 V/3.3 V systems), so they are not directly substitutable without matching the monitored rail.
Nominal Monitored Supply 5 V 3 V / 3.3 V The device must be selected to match the logic supply being supervised; using the wrong variant leaves the system either unprotected or falsely reset.
Reset Threshold Accuracy ±1.5% (over temperature) ±1.5% (over temperature) Tight threshold accuracy ensures consistent reset assertion across temperature and process variation; both parts share the same accuracy class.
Reset Output Type Active-low push-pull (RESET) with active-high (RESET) Active-low push-pull (RESET) with active-high (RESET) Output topology must match the microcontroller reset input polarity and drive requirements; identical here, so reset interfacing is compatible.
Manual Reset Input Yes (MR, active-low) Yes (MR, active-low) A manual reset input allows external system reset; both provide it, preserving board-level reset functionality.
Watchdog Timer Yes (1.6 s typ timeout) Yes (1.6 s typ timeout) The watchdog detects firmware lockups; identical timeout behavior means the same software servicing interval works for both.
Reset Timeout Delay 200 ms typ 200 ms typ Reset pulse width must be long enough for the processor to initialize; matching delay preserves startup timing.
Supply Voltage Range 1.0 V to 5.5 V (VCC operating) 1.0 V to 5.5 V (VCC operating) Defines the operating window and low-voltage behavior; identical ranges mean the same decoupling and rail design applies.
Package 8-lead SOIC (R-8) 8-lead SOIC (R-8) Footprint and pinout compatibility allow drop-in replacement on an existing PCB; both use the same SOIC-8 package.
Operating Temperature Range -40 °C to +85 °C -40 °C to +85 °C Industrial temperature range ensures reliable operation in harsh environments; identical ratings mean equivalent environmental suitability.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADM706ARZ ADM706PAR
Part Status Active Obsolete
Type Simple Reset/Power-On Reset Simple Reset/Power-On Reset
Number of Voltages Monitored 1 1
Voltage - Threshold 4.4V 2.63V
Output Push-Pull, Totem Pole Push-Pull, Totem Pole
Reset Active Low Active High
Reset Timeout 160ms Minimum 160ms Minimum
Operating Temperature -40°C ~ 85°C (TA) -40°C ~ 85°C (TA)
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the ADM706ARZ and ADM706PAR?

Both are Analog Devices microprocessor supervisory circuits in an 8-lead SOIC package with the same functional pinout. The primary difference is the reset threshold voltage: the ADM706ARZ has a typical reset threshold of 4.40 V (suitable for 5 V systems), while the ADM706PAR has a typical reset threshold of 2.63 V (suitable for 3.3 V systems). The suffix "P" denotes the lower-voltage threshold option.

Can the ADM706ARZ and ADM706PAR be substituted for each other directly?

No. Because their reset threshold voltages differ (4.40 V typical for the ADM706ARZ versus 2.63 V typical for the ADM706PAR), they are intended for different supply rails. Substitution requires verifying that the threshold matches the monitored supply voltage and that all other specifications meet the design requirements.

What supply voltage range does each device support?

The ADM706ARZ operates from a supply voltage of 4.75 V to 5.5 V, targeting 5 V systems. The ADM706PAR operates from 2.7 V to 3.6 V, targeting 3.3 V systems. The operating supply range should be confirmed against the respective Analog Devices datasheet for the specific grade.

Do both parts provide the same supervisory functions?

Yes. Both integrate a power-on reset generator, a manual reset input, a watchdog timer, and a 1.6 V/1.25 V threshold power-fail comparator in a single 8-lead SOIC package. The functional blocks are identical; the difference lies in the reset threshold and associated supply voltage range.

Are the pinouts and packages identical?

Yes. Both devices are offered in the same 8-lead SOIC (R-8) package with the same pin functions, including MR, VCC, GND, PFI, PFO, WDI, RESET, and RESET (complementary). This allows a common PCB footprint, but electrical threshold differences must still be validated before replacement.

What is the watchdog timeout period for these devices?

Both the ADM706ARZ and ADM706PAR feature a watchdog timer with a nominal timeout period of 1.6 seconds. If the watchdog input is not toggled within this window, the watchdog output asserts a reset. Designers should confirm the timeout tolerance in the Analog Devices datasheet.

Which part should be selected for a 3.3 V system?

The ADM706PAR is the appropriate choice for 3.3 V systems because its 2.63 V typical reset threshold ensures proper reset assertion before the supply falls below the operating range of 3.3 V logic. The ADM706ARZ, with a 4.40 V typical threshold, is intended for 5 V systems.