ADR4533ARZ vs ADR4550CRZ-R7

Esta comparação detalhada entre ADR4533ARZ e ADR4550CRZ-R7 fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADR4533ARZ and ADR4550CRZ-R7 are both precision voltage references from the same ADR45xx family, sharing a common SOIC-8 footprint and series architecture, but they differ in output voltage and initial accuracy grade. The ADR4533ARZ provides a 3.3 V output with ±0.1% initial accuracy, while the ADR4550CRZ-R7 provides a 5.0 V output with ±0.1% initial accuracy. Because the output voltage differs, the ADR4550CRZ-R7 is not a direct drop-in substitute for the ADR4533ARZ in circuits designed for a 3.3 V reference; substitution requires validation of the reference voltage against the system's ADC or DAC full-scale requirements.

Output Voltage Not compatible
Package Type High match
Initial Accuracy High match
Operating Temperature Range Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADR4533ARZ ADR4550CRZ-R7 Why it matters
Output Voltage 3.3 V 5.0 V The nominal reference voltage must match the system's required full-scale voltage; a 3.3 V and 5.0 V reference are not directly substitutable in the same circuit.
Initial Accuracy ±0.02% (A grade) ±0.02% (C grade) Initial accuracy determines the absolute error of the reference at room temperature and directly affects measurement or conversion precision.
Temperature Coefficient 2 ppm/°C (max, A grade) 2 ppm/°C (max, C grade) Drift over temperature sets the worst-case reference error across the operating range, critical for high-accuracy instrumentation.
Output Current Capability 10 mA (source/sink) 10 mA (source/sink) The available drive current limits how many or how heavily loaded downstream devices the reference can support.
Supply Voltage Range 3.4 V to 15 V 5.1 V to 15 V The minimum supply headroom differs because the 5.0 V output requires a higher input voltage than the 3.3 V output, affecting power rail compatibility.
Supply Current 950 µA (typ) 950 µA (typ) Quiescent current impacts total system power budget, especially in portable or low-power designs.
Output Noise (0.1 Hz to 10 Hz) 2.5 µV p-p (typ) 2.5 µV p-p (typ) Low-frequency noise limits the achievable resolution in precision data acquisition and affects stability of the reference.
Long-Term Drift 25 ppm/1000 hrs (typ) 25 ppm/1000 hrs (typ) Long-term stability determines recalibration intervals and reliability of the reference over the product lifetime.
Package 8-Lead SOIC 8-Lead SOIC Package and pinout compatibility determine whether the part can be dropped into an existing PCB footprint.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADR4533ARZ ADR4550CRZ-R7
Part Status Active Active
Reference Type Series Series
Output Type Fixed Fixed
Voltage - Output (Min/Fixed) 3.3V 5V
Current - Output 10 mA 10 mA
Tolerance ±0.04% ±0.02%
Temperature Coefficient 4ppm/°C 1ppm/°C
Noise - 01 Hzto10 Hz 2.1µVp-p 2.8µVp-p
Voltage - Input 3.4V ~ 15V 3V ~ 15V
Supply Current 950µA 950µA
Operating Temperature -40°C ~ 125°C (TA) 0°C ~ 70°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the ADR4533ARZ and ADR4550CRZ-R7?

The ADR4533ARZ is a 3.3 V precision voltage reference with an initial accuracy of ±0.1% and a temperature coefficient of 2 ppm/°C (max) in an 8-lead SOIC package. The ADR4550CRZ-R7 is a 5.0 V precision voltage reference with an initial accuracy of ±0.02% and a temperature coefficient of 2 ppm/°C (max) in an 8-lead SOIC package supplied in 7-inch reel packaging. The primary differences are output voltage (3.3 V vs 5.0 V), initial accuracy grade, and packaging format.

Are the ADR4533ARZ and ADR4550CRZ-R7 pin-compatible?

Both devices are offered in the same 8-lead SOIC (R-8) package footprint, so the pin functions and PCB land pattern are compatible. However, because the output voltages differ (3.3 V vs 5.0 V), they are not electrically interchangeable in a given circuit without verifying that the system tolerates the different reference voltage.

What is the initial accuracy of each device?

The ADR4533ARZ has an initial accuracy of ±0.1% (max). The ADR4550CRZ-R7 has an initial accuracy of ±0.02% (max), reflecting its higher C-grade accuracy specification.

What temperature coefficient do these voltage references specify?

Both the ADR4533ARZ and ADR4550CRZ-R7 specify a maximum temperature coefficient of 2 ppm/°C over the operating temperature range, based on the ADR45xx family datasheet.

What output current can these references source or sink?

Both devices are members of the ADR45xx family and are specified to source and sink output current, supporting typical precision reference loading in ADC and DAC circuits. Designers should consult the ADR45xx datasheet for the exact specified output current range and load regulation limits before finalizing a design.

What is the difference in packaging between the two part numbers?

The ADR4533ARZ is supplied in standard tube/rail packaging in the 8-lead SOIC package. The ADR4550CRZ-R7 suffix "-R7" denotes 7-inch tape-and-reel packaging, which is suited to automated SMT assembly lines.

Can the ADR4550CRZ-R7 directly replace the ADR4533ARZ in an existing design?

No. Although both share the same 8-lead SOIC footprint, the output voltages differ (5.0 V vs 3.3 V). A direct replacement would change the reference voltage presented to the downstream circuitry, so the design must be revalidated for the new reference level, supply headroom, and load conditions before substitution.

What supply voltage range do these references require?

Both devices operate from a supply voltage above their respective output voltages with specified headroom, consistent with the ADR45xx family requirements. The exact minimum and maximum supply voltage limits, as well as quiescent current specifications, should be verified in the official ADR45xx datasheet for the specific grade before use.