ADS1248IPW vs ADS1219IPWR

Esta comparação detalhada entre ADS1248IPW e ADS1219IPWR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1219IPWR and ADS1248IPW are not drop-in replacements for one another. Although both are 24-bit delta-sigma ADCs, they differ in resolution architecture, input channel configuration, package footprint, and reference/supply requirements, so a direct board-level substitution is not feasible without redesign.

Different channel count Different package footprint Different input configuration Different reference architecture

Parts at a glance

Part A

ADS1248IPW

Texas Instruments

Lifecycle
Active
Stock
2446 PCS
Package
TSSOP-28
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Part B

ADS1219IPWR

Texas Instruments

Lifecycle
Active
Stock
5923 PCS
Package
TSSOP-16
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1219IPWR ADS1248IPW Why it matters
Resolution (bits) 24 24 Both are 24-bit delta-sigma ADCs, so resolution alone does not differentiate them for substitutability.
Number of input channels 4 (single-ended) / 2 (differential) 8 (single-ended) / 4 (differential) Channel count determines how many sensors or signals can be measured; the ADS1248 supports twice as many inputs.
PGA gain stages 1 to 128 1 to 128 Programmable gain allows small signals to be amplified; both offer the same gain range.
Maximum data rate (SPS) 1000 2000 Higher throughput enables faster sampling; the ADS1248 can sample up to twice as fast.
Interface I2C SPI The digital interface must match the host microcontroller; I2C and SPI are not directly interchangeable without redesign.
Internal reference Yes (2.048 V) Yes (2.048 V) An internal reference simplifies design and improves accuracy; both integrate a 2.048 V reference.
Supply voltage (analog) 2.7 V to 5.5 V 2.7 V to 5.25 V Supply range affects compatibility with system rails; the ADS1219 tolerates a slightly higher maximum analog supply.
Package TSSOP-16 TSSOP-28 Footprint and pin count differ, so a board redesign is required to substitute one for the other.
Operating temperature range -40 °C to +125 °C -40 °C to +105 °C The wider temperature range of the ADS1219 suits harsher environments.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1248IPW ADS1219IPWR
Part Status Active Active
Number of Bits 24 24
Sampling Rate(Per Second) 2k 1k
Number of Inputs 4, 7 4
Input Type Differential, Single Ended Differential, Single Ended
Data Interface SPI I²C
Configuration MUX-PGA-ADC MUX-ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External, Internal External, Internal
Voltage - Supply, Analog 2.7V ~ 5.25V 2.3V ~ 5.5V
Voltage - Supply, Digital 2.7V ~ 5.25V 2.3V ~ 5.5V
Features PGA, Temperature Sensor PGA
Operating Temperature -40°C ~ 105°C -40°C ~ 125°C
Ratio - S / H: ADC - 0:1

Frequently asked questions

What are the primary differences between the ADS1219IPWR and ADS1248IPW?

The ADS1219IPWR is a 4-channel, 24-bit delta-sigma ADC with a fixed gain of 1 and an I2C interface, housed in a TSSOP-16 package. The ADS1248IPW is an 8-channel (4 differential), 24-bit delta-sigma ADC with a programmable gain amplifier (PGA) from 1 to 128, an SPI interface, and an integrated excitation current source, housed in a TSSOP-28 package.

Are the ADS1219IPWR and ADS1248IPW pin-to-pin or package compatible?

No. The ADS1219IPWR uses a 16-pin TSSOP package, while the ADS1248IPW uses a 28-pin TSSOP package. They have different pin counts, pin functions, and PCB land patterns, so they are not drop-in replacements for each other.

Do these ADCs use the same digital communication interface?

No. The ADS1219IPWR communicates via an I2C interface, whereas the ADS1248IPW uses an SPI-compatible interface. The host microcontroller firmware and bus wiring must be designed accordingly for each device.

How do the input channel counts and PGA capabilities compare?

The ADS1219IPWR provides 4 single-ended or 2 differential inputs with a fixed gain of 1. The ADS1248IPW provides 8 single-ended or 4 differential inputs and includes a programmable gain amplifier selectable from 1 to 128, making it better suited for low-level sensor signals.

Does the ADS1248IPW include sensor excitation features that the ADS1219IPWR lacks?

Yes. The ADS1248IPW integrates two matched programmable excitation current sources (typically used for RTD and thermistor measurements), while the ADS1219IPWR does not include built-in excitation current sources.

What are the supply voltage requirements for each device?

Both devices operate from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 2.7 V to 5.25 V, per their respective manufacturer datasheets. Designers should verify the exact recommended operating conditions in the latest datasheet revision.

Which device is more suitable for multi-channel RTD or thermocouple systems?

The ADS1248IPW is generally more suitable for multi-channel RTD or thermocouple systems because it offers 4 differential inputs, a PGA up to 128, and integrated excitation current sources. The ADS1219IPWR, with 2 differential inputs and fixed gain, suits simpler, lower-channel-count precision measurement designs.