Esta comparação detalhada entre ADS1220IPW e ADS1202IPWRG4 fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1220IPW and ADS1202IPWRG4 are not drop-in replacements for one another. The ADS1220IPW is a 24-bit precision delta-sigma ADC with an integrated PGA and SPI interface, while the ADS1202IPWRG4 is a 16-bit isolated delta-sigma modulator with a single-bit output stream. Their differing resolution, output architecture, and interface requirements make direct substitution impractical without redesigning the surrounding signal chain.

Different output type Different resolution Different interface Different signal chain

Parts at a glance

Part A

ADS1220IPW

Texas Instruments

Lifecycle
Active
Stock
4062 PCS
Package
TSSOP-16
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1220IPW ADS1202IPWRG4 Why it matters
Resolution (bits) 24 16 Resolution determines the smallest signal change the ADC can distinguish; a 24-bit device offers far finer measurement granularity than a 16-bit device.
Architecture Delta-Sigma (with PGA and input MUX) Delta-Sigma modulator The ADS1220 integrates a PGA and multiplexer for direct sensor connection, while the ADS1202 is a modulator-only device requiring external digital filtering, affecting system design and substitutability.
Number of input channels 4 (2 differential / 4 single-ended) 1 (differential) Channel count determines how many signals can be measured; the ADS1220 supports multi-channel sensing while the ADS1202 handles a single differential input.
Output interface SPI Digital bit-stream (modulator output) The output format dictates how the host processor reads data; SPI provides a standard register-based interface, whereas the ADS1202 outputs a raw modulator bit-stream needing external filtering.
Programmable gain amplifier (PGA) Yes (gain 1 to 128) No An integrated PGA allows direct amplification of small sensor signals, simplifying the analog front end; its absence in the ADS1202 requires external amplification.
Supply voltage (analog) 2.3 V to 5.5 V 4.5 V to 5.5 V The wider supply range of the ADS1220 allows operation from lower-voltage rails, while the ADS1202 requires a nominal 5 V supply, affecting power-supply compatibility.
Package TSSOP-16 TSSOP-8 Package footprint and pin count affect PCB layout and drop-in compatibility; the two devices are not pin-compatible.
Operating temperature range -40 °C to +125 °C -40 °C to +85 °C The wider temperature range of the ADS1220 suits harsher environments, whereas the ADS1202 is limited to standard industrial temperature conditions.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1220IPW ADS1202IPWRG4
Supplier - Texas Instruments
Part Status Active Discontinued at Digi-Key
Type - Modulator
Number of Channels - 1
Resolution(Bits) - 16 b
Sampling Rate(Per Second) 2k 40k
Data Interface SPI Serial
Voltage Supply Source - Single Supply
Voltage - Supply - 4.75V ~ 5.25V
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C
Mounting Type - Surface Mount
Number of Bits 24 -
Number of Inputs 2, 4 -
Input Type Differential, Single Ended -
Configuration MUX-PGA-ADC -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External, Internal, Supply -
Voltage - Supply, Analog 2.3V ~ 5.5V, ±2.5 -
Voltage - Supply, Digital 2.3V ~ 5.5V -
Features PGA, Temperature Sensor -

Frequently asked questions

What are the primary functional differences between the ADS1220IPW and ADS1202IPWRG4?

The ADS1220IPW is a 24-bit, 4-channel delta-sigma analog-to-digital converter (ADC) with an integrated programmable gain amplifier (PGA), voltage reference, and SPI interface, designed for precision sensor measurement. The ADS1202IPWRG4 is a 16-bit, single-channel delta-sigma modulator that outputs a 1-bit data stream for external digital filtering, typically used in isolated current-sense and motor-control applications. They differ fundamentally in resolution, channel count, output format, and integration level.

Are the ADS1220IPW and ADS1202IPWRG4 pin-compatible or directly interchangeable?

No. The ADS1220IPW is supplied in a 16-pin TSSOP (PW) package, while the ADS1202IPWRG4 is supplied in a 16-pin TSSOP (PW) package as well, but the pin functions and internal architecture differ. The ADS1220 provides a complete ADC with SPI and GPIO pins, whereas the ADS1202 provides a modulator with clock and data outputs. They are not directly interchangeable and require different external circuitry and firmware.

What are the resolution and output data format differences between the two devices?

The ADS1220IPW provides 24-bit resolution with a digital SPI output delivering fully converted codes. The ADS1202IPWRG4 is a 16-bit delta-sigma modulator that outputs a 1-bit serial bitstream (MDAT) at a rate determined by the external clock (MCLK), requiring an external digital filter (e.g., sinc filter) to reconstruct the 16-bit data word. The ADS1220 integrates the digital filter and outputs finished conversion results.

How do the input channel configurations compare between the ADS1220IPW and ADS1202IPWRG4?

The ADS1220IPW offers 4 single-ended or 2 differential input channels with an integrated PGA and input multiplexer. The ADS1202IPWRG4 provides a single differential input channel (AINP/AINN) intended for direct connection to a shunt or sensor, without an integrated multiplexer or PGA. Channel-count requirements therefore strongly influence device selection.

What are the supply voltage and interface differences between the ADS1220IPW and ADS1202IPWRG4?

The ADS1220IPW operates from an analog supply (AVDD) of 2.3 V to 5.5 V and a digital supply (DVDD) of 2.3 V to 5.5 V, with an SPI-compatible serial interface. The ADS1202IPWRG4 operates from a 5 V analog supply (AVDD) and a 3 V to 5.5 V digital supply (DVDD), with a modulator clock input (MCLK) and a 1-bit data output (MDAT). Interface and supply requirements must be matched to the host system.

Which device is better suited for isolated current-sensing or motor-control applications?

The ADS1202IPWRG4 is specifically intended for isolated current-sense and motor-control applications because its 1-bit modulator output can be transmitted across an isolation barrier (e.g., via a digital isolator) and filtered on the controller side. The ADS1220IPW, with its integrated PGA, reference, and SPI output, is better suited for precision multi-sensor measurement systems where isolation is not the primary requirement.

Do the ADS1220IPW and ADS1202IPWRG4 have different operating temperature ranges?

Both devices are specified for the industrial temperature range of -40°C to +125°C (TA), as documented in their respective manufacturer datasheets. Designers should still verify the specific grade and package suffix against the latest datasheet before finalizing thermal and reliability calculations.

Can the ADS1220IPW replace the ADS1202IPWRG4 in an existing design without firmware changes?

No. The ADS1220IPW outputs fully converted SPI data, while the ADS1202IPWRG4 outputs a 1-bit modulator stream requiring external digital filtering. Replacing one with the other requires changes to the host firmware, clocking scheme, and external filter or interface circuitry. A direct drop-in replacement is not possible.