ADS1222IPWR vs ADS1203IPWR

Esta comparação detalhada entre ADS1222IPWR e ADS1203IPWR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1222IPWR and ADS1203IPWR are not drop-in replacements for one another. Although both are 24-bit delta-sigma analog-to-digital converters in a TSSOP-16 package, they differ fundamentally in resolution architecture, output interface, channel configuration, and intended application domain, so a direct substitution is not feasible without a full system redesign.

Different output interface Different channel configuration Different conversion architecture Different application domain

Parts at a glance

Part A

ADS1222IPWR

Texas Instruments

Lifecycle
Active
Stock
3095 PCS
Package
TSSOP-14
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Part B

ADS1203IPWR

Texas Instruments

Lifecycle
Active
Stock
3345 PCS
Package
TSSOP-8
Series
Acquisição de dados - ADCs-DACs - Objetivo Especial

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1222IPWR ADS1203IPWR Why it matters
Resolution (bits) 24 16 Higher resolution enables finer measurement of small signal changes; a 24-bit ADC resolves much smaller increments than a 16-bit device.
Architecture Delta-Sigma (24-bit ADC) Delta-Sigma Modulator The ADS1222 is a complete ADC with digital output, while the ADS1203 is a modulator requiring external digital filtering, affecting system design and interface complexity.
Output Interface SPI-compatible serial 1-bit modulator bitstream Different output formats determine what downstream circuitry (microcontroller or digital filter) is needed to obtain usable data.
Input Channels 2 differential 1 differential Channel count affects how many signals can be measured without external multiplexing.
Data Rate / Sample Rate Up to 2 kSPS Up to 40 kSPS (modulator clock dependent) Sample rate determines the bandwidth of signals that can be captured and the tradeoff between speed and noise performance.
Supply Voltage 2.7 V to 5.5 V 4.5 V to 5.5 V Supply range affects compatibility with low-voltage logic and battery-powered systems; the ADS1222 supports lower supply voltages.
Package TSSOP-16 TSSOP-16 Package footprint determines PCB layout compatibility; identical packages allow drop-in replacement on the same board.
Internal PGA Yes (gain up to 128) No An internal programmable gain amplifier allows direct connection of low-level sensors without external amplification, simplifying the signal chain.
Operating Temperature Range -40°C to +85°C -40°C to +85°C Temperature range indicates suitability for industrial and harsh-environment applications.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1222IPWR ADS1203IPWR
Supplier - Texas Instruments,Rochester Electronics, LLC
Part Status Active Obsolete
Type - Modulator
Number of Channels - 1
Resolution(Bits) - 16 b
Sampling Rate(Per Second) 240 40k
Data Interface SPI Serial
Voltage Supply Source - Single Supply
Voltage - Supply - 4.75V ~ 5.25V
Operating Temperature -40°C ~ 85°C -40°C ~ 125°C
Mounting Type - Surface Mount
Number of Bits 24 -
Number of Inputs 2 -
Input Type Differential, Single Ended -
Configuration MUX-ADC -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External -
Voltage - Supply, Analog 2.7V ~ 5.5V -
Voltage - Supply, Digital 2.7V ~ 5.5V -
Features Temperature Sensor -

Frequently asked questions

What are the primary functional differences between the ADS1222IPWR and ADS1203IPWR?

The ADS1222IPWR is a 24-bit delta-sigma analog-to-digital converter with a two-channel differential input multiplexer, internal oscillator, and a programmable gain amplifier, communicating via a simple two-wire serial interface. The ADS1203IPWR is a 16-bit delta-sigma modulator that outputs a single-bit data stream for use with external digital filters, typically in isolated or high-speed current-sensing applications. They differ fundamentally in resolution, output format, and intended signal chain architecture.

Are the ADS1222IPWR and ADS1203IPWR pin-to-pin compatible?

No. Both devices are offered in a TSSOP-16 package (PW), but their pin functions and internal architectures differ. The ADS1222IPWR provides a complete ADC with serial data output, while the ADS1203IPWR provides a modulator data stream and clock output. Pin assignments and external component requirements are not interchangeable, so PCB layouts must be designed specifically for each device.

What are the resolution and output data formats of each device?

The ADS1222IPWR provides 24-bit resolution with a serial peripheral interface-compatible two-wire output for direct digital conversion results. The ADS1203IPWR is a 16-bit delta-sigma modulator that outputs a single-bit pulse-density-modulated data stream, requiring an external digital filter (such as an FPGA or DSP sinc filter) to reconstruct the digital word. The effective resolution of the ADS1203IPWR depends on the external filter implementation and oversampling ratio.

Can the ADS1203IPWR be used as a drop-in replacement for the ADS1222IPWR in an existing design?

No. The ADS1203IPWR does not provide a complete ADC output; it requires an external digital filter to convert its single-bit modulator stream into a usable digital value. Additionally, the pin functions, supply requirements, and interface signals differ from the ADS1222IPWR. A direct substitution is not possible without redesigning the digital signal processing chain and PCB layout.

What are the typical supply voltage requirements for these two devices?

The ADS1222IPWR operates from a single analog supply of 2.7 V to 5.5 V, with a separate digital supply of 2.7 V to 5.5 V. The ADS1203IPWR operates from a single 5 V analog supply and a 2.7 V to 5.5 V digital supply. Designers should verify exact supply ranges and decoupling requirements against the respective manufacturer datasheets before finalizing power architectures.

Which device is better suited for isolated current-sensing applications?

The ADS1203IPWR is specifically designed for isolated current-sensing and power-monitoring applications because its single-bit modulator output can be easily galvanically isolated using digital isolators before external filtering. The ADS1222IPWR, with its complete ADC and serial interface, is more suited to direct sensor measurement and general-purpose data acquisition where isolation is not a primary requirement.

Do both devices support the same serial interface protocol?

No. The ADS1222IPWR uses a two-wire serial interface for reading conversion results and configuring the device. The ADS1203IPWR outputs a single-bit modulator data stream along with a clock signal, and does not implement a command-based serial protocol. Interfacing the ADS1203IPWR requires a digital filter or modulator-specific receiver, not a standard SPI or I2C host interface.