ADS1240E vs ADS1253EG4

Esta comparação detalhada entre ADS1240E e ADS1253EG4 fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1240E and ADS1253EG4 are both 24-bit delta-sigma ADCs, but they differ in resolution architecture, input channel configuration, package footprint, and interface timing, so the ADS1253EG4 cannot be used as a direct drop-in substitute for the ADS1240E without redesign and validation.

Different channel count Different package footprint Different data rate Different interface timing

Parts at a glance

Part A

ADS1240E

Texas Instruments

Lifecycle
Active
Stock
5619 PCS
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Part B

ADS1253EG4

Texas Instruments

Lifecycle
Active
Stock
537 PCS
Package
SSOP-16
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1240E ADS1253EG4 Why it matters
Resolution (bits) 24 24 Both are 24-bit delta-sigma ADCs, so resolution is equivalent for high-precision measurement applications.
Number of input channels 4 (differential) 1 (differential) The ADS1240E supports multiple differential inputs, while the ADS1253EG4 is single-channel; this affects how many signals can be measured without external multiplexing.
Maximum data rate (SPS) 15 20000 The ADS1253EG4 offers a much higher sampling rate, making it suitable for faster dynamic signals, whereas the ADS1240E targets slow, high-accuracy measurements.
Interface type SPI (serial) SPI (serial) Both use a serial SPI interface, simplifying digital connection to microcontrollers and DSPs.
Supply voltage (analog) 2.7 V to 5.25 V 4.75 V to 5.25 V The ADS1240E operates over a wider low-voltage range, while the ADS1253EG4 requires a nominal 5 V supply, affecting system power design.
PGA / gain stage Yes (on-chip PGA) No (fixed gain) An on-chip PGA in the ADS1240E allows direct amplification of small sensor signals, whereas the ADS1253EG4 requires external signal conditioning.
Package type SSOP-20 SSOP-16 Different package pin counts and footprints affect PCB layout and drop-in substitutability.
Operating temperature range -40 °C to +85 °C -40 °C to +85 °C Both cover the industrial temperature range, so environmental suitability is equivalent.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1240E ADS1253EG4
Supplier - Rochester Electronics, LLC,Texas Instruments
Part Status Active Discontinued at Digi-Key
Number of Bits 24 24
Sampling Rate(Per Second) - 20k
Number of Inputs 4 4
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration MUX-PGA-ADC MUX-ADC
Number of A/D Converters - 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 2.7V ~ 3.3V, 5V 5V
Voltage - Supply, Digital 2.7V ~ 5.25V 5V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Base Product Number ADS1240 -
Sampling Rate (Per Second) 15 -
Number of A / D Converters 1 -
Features PGA -
Mounting Type Surface Mount -
Packaging Tube -

Frequently asked questions

What are the primary differences between the ADS1240E and ADS1253EG4?

The ADS1240E is a 24-bit delta-sigma ADC with a programmable gain amplifier (PGA) and a maximum data rate of 15 SPS, housed in a 24-pin TSSOP package. The ADS1253EG4 is a 24-bit delta-sigma ADC without an integrated PGA, offering a higher maximum data rate of 20.8 kSPS, and is supplied in a 16-pin SSOP package. The ADS1240E targets low-speed, high-resolution sensor applications, while the ADS1253EG4 suits higher-speed data acquisition.

Are the ADS1240E and ADS1253EG4 pin-to-pin compatible?

No. The ADS1240E uses a 24-pin TSSOP package, while the ADS1253EG4 uses a 16-pin SSOP package. The pin counts, pin functions, and package footprints differ, so they are not direct drop-in replacements and require separate PCB layouts.

Do both devices include a programmable gain amplifier (PGA)?

No. The ADS1240E integrates a PGA that supports gains from 1 to 128, allowing direct connection of low-level sensor signals. The ADS1253EG4 does not include an on-chip PGA; external signal conditioning or amplification is required for low-level inputs.

How do the maximum data rates of the ADS1240E and ADS1253EG4 compare?

The ADS1240E supports data rates up to 15 SPS, optimized for high-resolution, low-speed measurements. The ADS1253EG4 supports data rates up to 20.8 kSPS, making it suitable for faster acquisition requirements. The trade-off is that higher output rates generally reduce effective resolution and noise performance.

What are the supply voltage requirements for the ADS1240E and ADS1253EG4?

Both devices operate from a single 5 V analog supply (AVDD) and a 2.7 V to 5.25 V digital supply (DVDD), per their respective manufacturer datasheets. Designers should verify the exact recommended operating conditions in the official Texas Instruments datasheets before finalizing power supply designs.

Which device is better suited for low-level sensor measurements such as thermocouples or RTDs?

The ADS1240E is generally better suited for low-level sensor measurements because its integrated PGA (gains up to 128) allows small sensor signals to be amplified before conversion, improving effective resolution. The ADS1253EG4 lacks an internal PGA, so low-level signals would require external amplification.

Can the ADS1253EG4 replace the ADS1240E in an existing design without firmware changes?

No. The two devices differ in package, pinout, register set, and command structure. The ADS1240E and ADS1253EG4 have different SPI command interfaces and configuration registers, so firmware and PCB layout changes are required. A direct substitution without redesign is not supported.

What are the package and operating temperature range specifications for both devices?

The ADS1240E is offered in a 24-pin TSSOP package, and the ADS1253EG4 in a 16-pin SSOP package. Both are specified for the industrial temperature range of -40°C to +85°C according to their Texas Instruments datasheets. Designers should confirm the exact package suffix and temperature grade against the ordering information in the official datasheets.