ADS1256IDBR vs ADS1213EG4

Esta comparação detalhada entre ADS1256IDBR e ADS1213EG4 fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1256IDBR and ADS1213EG4 are not drop-in replacements for one another. Although both are 24-bit delta-sigma analog-to-digital converters, they differ in resolution architecture, input channel configuration, package footprint, and digital interface, so a direct board-level substitution is not possible without redesign.

Different input channel configuration Different digital interface Different package footprint Different conversion architecture

Parts at a glance

Part A

ADS1256IDBR

Texas Instruments

Lifecycle
Active
Stock
4327 PCS
Package
SSOP-28
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Part B

ADS1213EG4

Texas Instruments

Lifecycle
Active
Stock
7697 PCS
Package
SSOP-28
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1256IDBR ADS1213EG4 Why it matters
Resolution (bits) 24 22 Higher resolution provides finer measurement granularity and lower quantization noise, which is critical for precision sensor and instrumentation applications.
Maximum Sample Rate (SPS) 30k 780 The sample rate determines the maximum signal bandwidth that can be captured; a much faster converter supports higher-frequency signals and faster multiplexed scanning.
Number of Input Channels 8 (single-ended) / 4 (differential) 4 (differential) Channel count affects how many sensors or signal sources can be connected without external multiplexing, impacting system complexity and cost.
Interface Type SPI SPI The digital interface must match the host microcontroller; both use SPI, but timing and register protocols differ and require firmware changes.
Supply Voltage (analog) 5 V 5 V Analog supply voltage determines the input voltage range and must be compatible with the sensor output swing and system power rails.
Package / Mounting 28-SSOP (surface mount) 28-SOIC (surface mount) Package footprint and pinout must match the PCB layout; different packages require board redesign and cannot be drop-in substituted.
Internal PGA Gain Range 1 to 64 1 to 16 Programmable gain amplifies small sensor signals before conversion; a wider gain range allows direct connection of lower-level signals without external amplification.
Operating Temperature Range -40°C to +85°C -40°C to +85°C The temperature range defines the environments in which the part is guaranteed to meet specifications, affecting suitability for industrial and outdoor use.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1256IDBR ADS1213EG4
Supplier - Texas Instruments
Part Status Active Obsolete
Number of Bits 24 22
Sampling Rate(Per Second) 30k 6.25k
Number of Inputs 4, 8 4
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration MUX-PGA-ADC MUX-PGA-ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External, Internal
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 1.8V ~ 3.6V 5V
Features PGA PGA
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C

Frequently asked questions

What are the primary differences between the ADS1256IDBR and the ADS1213EG4?

The ADS1256IDBR is a 24-bit, 8-channel delta-sigma ADC with a maximum data rate of 30 kSPS, housed in a 28-pin SSOP package. The ADS1213EG4 is a 22-bit, 4-channel delta-sigma ADC with a maximum data rate of 6.25 kSPS, housed in a 28-pin SOIC package. The ADS1256 offers higher resolution, more input channels, and faster throughput, while the ADS1213 provides 22-bit resolution with a different channel count and package footprint.

Are the ADS1256IDBR and ADS1213EG4 pin-to-pin compatible?

No. The ADS1256IDBR uses a 28-pin SSOP (DB) package, while the ADS1213EG4 uses a 28-pin SOIC (DW) package. The package types and pin assignments differ, so they are not directly pin-to-pin compatible and cannot be interchanged without PCB redesign.

Can the ADS1256IDBR and ADS1213EG4 operate from the same supply voltage?

The ADS1256IDBR operates from a single 5 V analog supply (AVDD) and a 1.8 V to 3.6 V digital supply (DVDD). The ADS1213EG4 operates from a single 5 V supply. While both use a 5 V analog supply, the ADS1256 supports a separate lower-voltage digital supply, whereas the ADS1213 uses a single 5 V supply for both analog and digital domains.

How do the resolution and data rates of the ADS1256IDBR and ADS1213EG4 compare?

The ADS1256IDBR provides 24-bit resolution with programmable data rates up to 30 kSPS. The ADS1213EG4 provides 22-bit resolution with a maximum data rate of 6.25 kSPS. The ADS1256 therefore offers higher resolution and approximately five times the maximum throughput of the ADS1213.

How many input channels does each device support?

The ADS1256IDBR provides 8 single-ended inputs or 4 differential inputs. The ADS1213EG4 provides 4 single-ended inputs or 2 differential inputs. The ADS1256 supports twice the channel count of the ADS1213.

Do both devices support a programmable gain amplifier (PGA)?

Yes. Both the ADS1256IDBR and the ADS1213EG4 include an on-chip programmable gain amplifier. The ADS1256 offers selectable gains of 1, 2, 4, 8, 16, 32, and 64. The ADS1213 offers selectable gains of 1, 2, 4, 8, 16, 32, 64, and 128. The available gain settings should be confirmed against the respective manufacturer datasheets for the specific operating conditions.

What serial interfaces do the ADS1256IDBR and ADS1213EG4 use?

The ADS1256IDBR uses an SPI-compatible serial interface. The ADS1213EG4 uses a synchronous serial interface that is also SPI-compatible. Both devices support microcontroller-based serial communication, but the exact timing and register protocols differ and must be implemented per each device's datasheet.

Which device is better suited for high-channel-count, high-speed data acquisition?

The ADS1256IDBR is better suited for high-channel-count, higher-speed applications because it offers 8 single-ended or 4 differential inputs and data rates up to 30 kSPS at 24-bit resolution. The ADS1213EG4, with 4 single-ended or 2 differential inputs and a maximum 6.25 kSPS data rate at 22-bit resolution, is more appropriate for lower-channel-count, lower-speed precision measurement applications.