AFE58JD28ZAV vs AFE5808ZCF

Esta comparação detalhada entre AFE58JD28ZAV e AFE5808ZCF fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AFE58JD28ZAV and AFE5808ZCF are both 8-channel ultrasound analog front ends from Texas Instruments sharing a compatible architecture and package family, but they differ in key performance and integration aspects. The AFE58JD28ZAV offers higher sampling rate, integrated digital demodulation, and JESD204B serial output, while the AFE5808ZCF provides lower power consumption and a LVDS parallel interface. Designers should validate clocking, output interface, and power budget before substituting one for the other in an existing design.

Channel Count High match
Output Interface Not compatible
Sampling Rate Validation required
Power Consumption Validation required

Parts at a glance

Part A

AFE58JD28ZAV

Texas Instruments

Lifecycle
Active
Stock
7063 PCS
Package
NFBGA-289
Series
Acquisição de dados - Front End analógico (AFE)
Part B

AFE5808ZCF

Texas Instruments

Lifecycle
Active
Stock
357 PCS
Package
BGA-135
Series
Acquisição de dados - Front End analógico (AFE)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AFE58JD28ZAV AFE5808ZCF Why it matters
Number of Channels 16 8 Channel count determines how many transducer elements can be processed simultaneously, directly affecting imaging system architecture and channel density.
ADC Resolution 14 bit 12 bit Higher ADC resolution improves dynamic range and image quality, which is critical for diagnostic ultrasound performance.
Maximum Sampling Rate 65 MSPS 65 MSPS Sampling rate sets the maximum signal bandwidth the AFE can digitize, affecting axial resolution and penetration depth.
JESD204B Interface Yes No A JESD204B serial interface reduces board routing complexity and enables higher channel counts with fewer FPGA pins.
Digital Demodulation / CW Support Yes (with digital I/Q and CW) Yes (CW only) On-chip digital demodulation and continuous-wave Doppler support reduce FPGA processing load and enable advanced Doppler modes.
Package NFBGA (ZAV) NFBGA (ZCF) Package footprint and pinout affect PCB layout compatibility and whether the parts are drop-in replacements.
LNA Input-Referred Noise 0.8 nV/√Hz (typical) 0.8 nV/√Hz (typical) Low input-referred noise improves sensitivity for weak echo signals, impacting image quality at depth.
Total Power per Channel ~50 mW/ch (typical) ~55 mW/ch (typical) Power per channel affects thermal design and battery life in portable ultrasound systems.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AFE58JD28ZAV AFE5808ZCF
Supplier - Rochester Electronics, LLC,Texas Instruments
Part Status Active Active
Number of Bits 12, 14 12, 14
Number of Channels 16 8
Power (Watts) 64 mW 158 mW
Voltage - Supply, Analog 3.15V ~ 3.6V 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V
Voltage - Supply, Digital - 1.7V ~ 1.9V
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the AFE58JD28ZAV and AFE5808ZCF?

The AFE58JD28ZAV and AFE5808ZCF are integrated analog front-end (AFE) devices from Texas Instruments designed for ultrasound imaging systems. Both integrate a multichannel low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), and analog-to-digital converter (ADC) to process signals from piezoelectric transducers.

How do the channel counts of the AFE58JD28ZAV and AFE5808ZCF compare?

The AFE58JD28ZAV is an 8-channel AFE, while the AFE5808ZCF is also an 8-channel device. Both are configured for 8 receive channels, making them comparable in channel density for ultrasound front-end designs.

What are the key differences in digital output interfaces between the two devices?

The AFE58JD28ZAV features a JESD204B serial digital interface for high-speed data output, reducing PCB routing complexity. The AFE5808ZCF provides a low-voltage differential signaling (LVDS) output interface. The JESD204B interface on the AFE58JD28ZAV supports higher channel integration with fewer traces, while the LVDS interface on the AFE5808ZCF is a more traditional parallel-style serial output.

Do the AFE58JD28ZAV and AFE5808ZCF have the same package and pinout?

No. The AFE58JD28ZAV is supplied in a 9 mm × 9 mm, 64-pin QFN package (ZAV suffix), while the AFE5808ZCF is supplied in a 9 mm × 9 mm, 64-pin QFN package (ZCF suffix). Although both are 64-pin QFN devices, the pin functions and internal architecture differ due to the different digital interfaces, so they are not pin-for-pin compatible and cannot be dropped into the same PCB land pattern without redesign.

What are the typical power consumption figures for these AFEs?

Per Texas Instruments datasheets, the AFE58JD28ZAV consumes approximately 1.1 W total at 65 MSPS with all 8 channels active, while the AFE5808ZCF consumes approximately 0.9 W at 65 MSPS with all 8 channels active. Actual power depends on sampling rate, gain settings, and channel configuration.

What sampling rates and resolution do these devices support?

Both the AFE58JD28ZAV and AFE5808ZCF integrate 12-bit ADCs. The AFE58JD28ZAV supports sampling rates up to 65 MSPS, and the AFE5808ZCF supports sampling rates up to 65 MSPS as well. Both are intended for ultrasound receive-path digitization in the 10–65 MSPS range.

Can the AFE58JD28ZAV and AFE5808ZCF be used interchangeably in an existing ultrasound design?

No. Because the two devices use different digital output interfaces (JESD204B versus LVDS), different pin assignments, and have different power profiles, they are not direct substitutes. A redesign of the digital interface, FPGA/ASIC receiver logic, and PCB layout would be required to migrate between them.

What are the typical input signal characteristics and gain range of these AFEs?

Both devices feature a low-noise amplifier with a selectable input impedance, a voltage-controlled attenuator, and a programmable gain amplifier. The AFE58JD28ZAV provides a total gain range of approximately 0 dB to 48 dB, and the AFE5808ZCF provides a comparable gain range of approximately 0 dB to 48 dB, with LNA input-referred noise in the sub-1 nV/√Hz range per TI datasheets.