AMC1311DWV vs AMC1306M25DWVR

Esta comparação detalhada entre AMC1311DWV e AMC1306M25DWVR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The AMC1306M25DWVR and AMC1311DWV are not drop-in replacements for each other. The AMC1306M25DWVR is a ±250 mV input, isolated delta-sigma modulator with a 1-bit Manchester-coded bitstream output, while the AMC1311DWV is a ±1 V input, isolated amplifier with a differential analog output. Their input voltage ranges, output signal types, and functional architectures differ fundamentally, so they serve different signal-chain roles and cannot be interchanged without redesigning the surrounding circuitry.

Different output type Different input voltage range Different signal architecture Different interface requirements

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AMC1306M25DWVR AMC1311DWV Why it matters
Input Signal Type Current shunt (differential voltage input, ±250 mV) Voltage (high-impedance, ±1 V input) Determines what physical quantity the device measures; a current-sense modulator cannot directly replace a voltage-sense amplifier without redesigning the sensing front end.
Output Interface 1-bit delta-sigma modulator (bitstream) Analog differential output The downstream signal chain differs fundamentally: the modulator requires a digital filter/decimator, while the amplifier feeds an ADC or analog control loop.
Input Voltage Range ±250 mV (linear input range) ±1 V (linear input range) Defines the maximum sense signal before clipping; mismatched ranges require different shunt or divider scaling.
Gain Fixed gain of 8 (modulator output density) Fixed gain of 1 (unity) Affects overall system scaling and resolution allocation; gain differences change the effective full-scale mapping.
Isolation Rating Reinforced isolation, 5 kV RMS (per datasheet) Reinforced isolation, 5 kV RMS (per datasheet) Both provide comparable safety isolation, so isolation is not a differentiator for substitutability.
Supply Voltage 3.3 V (high side) / 3.3 V or 5 V (low side) 3.3 V (high side) / 3.3 V or 5 V (low side) Power rail compatibility is similar, easing board-level integration for either device.
Package 8-pin SOIC (DW) 8-pin SOIC (DWV) Footprint and pinout compatibility affect whether a drop-in replacement is physically possible.
Operating Temperature Range -40°C to +125°C -40°C to +125°C Identical temperature ratings mean environmental constraints do not differentiate the two parts.
Typical Application Motor drive current sensing, shunt-based current measurement Isolated voltage sensing (e.g., DC-link, inverter output voltage) The intended measurement function differs, so they are not functionally substitutable despite similar isolation and package.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AMC1311DWV AMC1306M25DWVR
Part Status Active Active
Type Isolation Isolated Module
Mounting Type Surface Mount Surface Mount
Number of Channels - 1
Resolution(Bits) - 16 b
Sampling Rate(Per Second) - 78k
Data Interface - CMOS, Serial
Voltage Supply Source - Analog and Digital
Voltage - Supply - 2.7V ~ 5.5V
Operating Temperature - -40°C ~ 125°C

Frequently asked questions

What are the fundamental functional differences between the AMC1306M25DWVR and the AMC1311DWV?

The AMC1306M25DWVR is a precision isolated delta-sigma modulator with a ±250 mV input range, designed for direct shunt-resistor current sensing. The AMC1311DWV is an isolated amplifier with a ±1 V input range and a fixed gain of 1, intended for isolated voltage sensing. They serve different signal-chain roles and are not functionally interchangeable.

Do the AMC1306M25DWVR and AMC1311DWV share the same package and pinout?

Both devices are offered in a 16-pin SOIC (DWV) package, but their pin functions and output interfaces differ. The AMC1306M25DWVR provides a single-bit delta-sigma bitstream output, while the AMC1311DWV provides a differential analog output. PCB layouts and downstream circuitry must be designed accordingly.

What are the input voltage ranges of the AMC1306M25DWVR and AMC1311DWV?

The AMC1306M25DWVR has a specified input range of ±250 mV, optimized for low-level shunt voltage drops. The AMC1311DWV has a specified input range of ±1 V, suited for higher-level voltage sensing through a resistor divider. Applying signals outside these ranges will not produce valid linear outputs.

What output formats do these two devices provide?

The AMC1306M25DWVR outputs a Manchester-encoded or unencoded single-bit delta-sigma bitstream that requires a digital filter (e.g., sinc filter) on the controller side to reconstruct the sample. The AMC1311DWV outputs a differential analog voltage with a fixed gain of 1, which can be fed directly to an ADC or analog control loop.

What are the isolation ratings of the AMC1306M25DWVR and AMC1311DWV?

Both devices are reinforced isolated components rated for 5 kV RMS isolation (per UL 1577) and are specified for a maximum working isolation voltage of 1.5 kV peak per VDE V 0884-11. Designers should confirm the exact certification and working-voltage ratings in the respective manufacturer datasheets for the target application.

Can the AMC1306M25DWVR directly replace the AMC1311DWV in an existing design?

No. The two parts differ in input range, output format, and signal-chain requirements. The AMC1306M25DWVR requires a digital filter and a modulator clock, whereas the AMC1311DWV provides an analog output. A direct drop-in replacement is not possible without redesigning the sensing front end and the receiving circuitry.

Which device is better suited for shunt-based current sensing versus voltage sensing?

The AMC1306M25DWVR is intended for shunt-based current sensing because its ±250 mV input range matches typical shunt voltage drops and its bitstream output suits isolated current-loop control. The AMC1311DWV is intended for isolated voltage sensing, such as DC-link or phase-voltage measurement, because its ±1 V input range accommodates divided voltage signals and its analog output interfaces directly with ADCs.

What supply voltages do the AMC1306M25DWVR and AMC1311DWV require?

Both devices use a dual-supply arrangement with a high-side supply (AVDD) and a low-side supply (DVDD). The AMC1306M25DWVR operates with a 5 V high-side supply and a 3.3 V or 5 V low-side supply, while the AMC1311DWV operates with a 5 V high-side supply and a 3.3 V or 5 V low-side supply. Exact recommended operating conditions should be verified in the respective datasheets.