Especificações
| Atributo | Valor |
| Series | HIH-4000 |
| Part Status | Active |
| Sensor Type | Humidity |
| Humidity Range | 0 ~ 100% RH |
| Output Type | Analog Voltage |
| Output | 3.198V @ 75.3%RH |
| Accuracy | ±3.5% RH |
| Response Time | 5 s |
| Voltage - Supply | 4V ~ 5.8V |
| Mounting Type | Through Hole |
| Operating Temperature | -40°C ~ 85°C |
| Package / Case | Housed Sensor |
| Base Product Number | HIH-4000 |
Visão Geral
Description
Key features of the HIH-4000-002 include its wide operating temperature range, low power consumption, and fast response time. The device is also factory-calibrated, ensuring high precision and consistency across different units. It operates with a supply voltage between 4 V to 5.8 V and provides an output voltage range that can be easily interfaced with microcontrollers or analog-to-digital converters for digital processing.
Overall, the HIH-4000-002 is valued for its simplicity, ease of integration, and reliable performance in a variety of humidity sensing applications. Its robust design makes it suitable for both consumer and industrial applications where accurate humidity measurement is crucial.
Equivalent
Features
1. High Accuracy: Provides typically ±3.5% RH accuracy, making it suitable for applications requiring precise humidity measurements.
2. Wide Operating Range: Functions effectively in a humidity range from 0% to 100% RH and temperature range from -40°C to 85°C, enabling use in diverse environments.
3. Linear Voltage Output: Offers a linear voltage output proportional to humidity levels, simplifying integration with various systems.
4. Fast Response Time: Capable of rapidly detecting changes in humidity, which is advantageous for dynamic environments.
5. Compact Design: Small form factor allows for easy integration into compact devices and systems.
6. Low Power Consumption: Designed to operate with low power, making it suitable for battery-powered and portable applications.
7. Durability: Built to withstand harsh conditions, ensuring long-term reliability.
These features make the HIH-4000-002 ideal for applications in HVAC systems, weather stations, industrial controls, and other fields requiring precise humidity monitoring.
Pinout
1. Pin 1 (Vcc): This is the power supply pin, where a voltage supply is connected, typically ranging from 4V to 5.8V.
2. Pin 2 (GND): This is the ground pin, used to complete the electrical circuit.
3. Pin 3 (OUT): The output pin provides an analog voltage output that is proportional to the relative humidity.
The HIH-4000-002 is designed for accurate, reliable humidity measurement and offers a near-linear voltage output, making it easy to interface with microcontrollers or other analog-to-digital converters.