Imagens apenas para referência
MAX86160AEFN+
+Lista de MateriaisIC
-
FabricanteAnalog Devices Inc./Maxim Integrated
-
Peça do Fabricante #MAX86160AEFN+
-
Pacote LFLGA-18
-
Em Estoque3628
365 Garantia de Qualidade em 1 dia
7*24 Garantia de serviço em 24 horas
90-Garantia de pós-venda em 1 dia
Garantia de Produto Genuíno
Especificações
| Atributo | Valor |
| Package / Case | Bulk |
| Part Status | Obsolete |
| Type | Integrated Heart Rate Sensor |
| Mounting Type | Surface Mount |
Visão Geral
Description
Key features of the MAX86160AEFN+ include low power consumption, a high dynamic range, ambient light cancellation, and a flexible sampling rate. It supports I²C communication for easy integration with microcontrollers and offers programmable settings to tailor performance according to specific application needs. The small size and efficient operation make it ideal for continuous monitoring applications where battery life is crucial. This device is part of Maxim Integrated's portfolio, now under Analog Devices, providing robust solutions for portable health monitoring technologies.
Equivalent
Features
1. Optical Sensing: Measures heart rate, blood oxygen saturation (SpO2), and other bio signals.
2. Low Power Consumption: Optimized for battery-operated devices, minimizing energy usage.
3. Compact Size: Its small footprint makes it ideal for wearable technology.
4. Configurable: Offers programmable sample rates and LED currents for flexible operation.
5. Integration: Combines multiple components into a single module, reducing the need for external parts.
6. Interference Reduction: Includes ambient light cancellation to improve accuracy in various lighting conditions.
7. I2C Interface: Provides a simple communication protocol for data retrieval and configuration.
8. High Sensitivity: Designed to function effectively in low-signal conditions.
These features make the MAX86160AEFN+ suitable for devices such as fitness trackers and smartwatches, which require compact and efficient biometric monitoring.
Pinout
Key functions of the MAX86160AEFN+ include:
1. Photoplethysmography (PPG) sensing: Utilizes integrated photodetectors and LEDs to measure changes in blood volume.
2. Low Power Consumption: Optimized for battery-powered devices.
3. Digital Interface: Communicates via an I2C interface, allowing easy integration with microcontrollers.
4. On-chip Temperature Sensor: Provides ambient temperature data.
5. Programmable Sample Rates and LED Currents: Offers flexibility for different applications and power management.
This sensor is widely used in smartwatches, fitness bands, and other portable health monitoring devices due to its small size and efficient operation.