ADS1282HIPWR
Texas Instruments
- Lifecycle
- Active
- Stock
- 5203 PCS
- Series
- Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Esta comparação detalhada entre ADS1282HIPWR e ADS1219IPWR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.
Replacement verdict
The ADS1219IPWR and ADS1282HIPWR are not drop-in replacements for one another. The ADS1219IPWR is a 24-bit, 4-channel delta-sigma ADC with an I2C interface in a TSSOP-16 package, while the ADS1282HIPWR is a 31-bit, 2-channel delta-sigma ADC with an SPI interface in a TSSOP-28 package. Their differing resolution, channel count, digital interface, package footprint, and target application domains make direct substitution impractical without a full system redesign.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1219IPWR | ADS1282HIPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 31 | Higher resolution enables finer measurement of small signal changes, which is critical for precision seismic and high-dynamic-range applications. |
| Number of input channels | 4 (differential/single-ended) | 2 (differential) | Channel count determines how many independent signals can be digitized without external multiplexing, affecting system architecture and board space. |
| Maximum sample rate | 1 kSPS | 4 kSPS | Sample rate sets the bandwidth of signals that can be captured; higher rates support faster-changing inputs and wider signal bandwidth. |
| Interface type | I2C | SPI | The digital interface must match the host microcontroller or FPGA, so a different bus can require hardware and firmware redesign. |
| Supply voltage (analog) | 2.7 V to 5.5 V | 5 V (analog, ±2.5 V bipolar) | Supply requirements affect power design and compatibility with existing rails; a different analog supply may need additional regulation. |
| PGA / gain stage | Integrated PGA (gain 1 to 128) | Integrated PGA (gain 1 to 64) | On-chip gain allows direct connection of low-level sensors; differing gain ranges change the smallest detectable input signal. |
| Package | TSSOP-16 | TSSOP-28 | Package footprint and pin count must match the PCB layout; a different package requires a board redesign and cannot be drop-in substituted. |
| Operating temperature range | -40 °C to +125 °C | -40 °C to +85 °C | The temperature range determines suitability for harsh or industrial environments; a narrower range may limit use in high-temperature applications. |
| Typical application focus | General-purpose precision sensing, portable instrumentation | Seismic and energy exploration, high-resolution data acquisition | Application focus indicates the intended noise, linearity, and bandwidth trade-offs, helping judge functional substitutability in a given design. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1282HIPWR | ADS1219IPWR |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 31 | 24 |
| Sampling Rate (Per Second) | 4k | - |
| Number of Inputs | 2 | 4 |
| Input Type | Differential | Differential, Single Ended |
| Data Interface | SPI | I²C |
| Configuration | ADC | MUX-ADC |
| Number of A / D Converters | 1 | - |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External, Internal |
| Voltage - Supply, Analog | 5V | 2.3V ~ 5.5V |
| Voltage - Supply, Digital | 1.65V ~ 3.6V | 2.3V ~ 5.5V |
| Features | PGA | PGA |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 125°C |
| Mounting Type | Surface Mount | - |
| Base Product Number | ADS1282 | - |
| Sampling Rate(Per Second) | - | 1k |
| Ratio - S / H: ADC | - | 0:1 |
| Number of A/D Converters | - | 1 |
The ADS1219IPWR is a 24-bit, 4-channel, delta-sigma ADC with an I2C interface, operating from a single 2.7 V to 5.5 V supply and housed in a TSSOP-16 package. The ADS1282HIPWR is a 31-bit, 2-channel, delta-sigma ADC with an SPI interface, designed for high-resolution seismic and energy exploration applications, operating from a 5 V analog supply and housed in a TSSOP-28 package. They differ in resolution, channel count, interface, supply requirements, and package footprint.
No. The two devices have different pin counts (16 vs 28), different package sizes (TSSOP-16 vs TSSOP-28), different serial interfaces (I2C vs SPI), and different supply voltage requirements. A direct drop-in replacement is not possible without PCB redesign and firmware changes.
The ADS1219IPWR provides 24-bit resolution with programmable data rates from 20 SPS to 1 kSPS. The ADS1282HIPWR provides 31-bit resolution with data rates from 250 SPS to 4 kSPS. The ADS1282HIPWR targets higher-resolution, higher-speed precision applications, while the ADS1219IPWR targets lower-speed, multi-channel general-purpose sensing.
The ADS1219IPWR offers 4 single-ended or 2 differential input channels with a programmable gain amplifier. The ADS1282HIPWR offers 2 differential input channels with a low-noise PGA. The ADS1219IPWR suits multi-channel sensor monitoring, while the ADS1282HIPWR suits dual-channel high-resolution seismic or vibration measurement.
The ADS1219IPWR uses an I2C interface supporting standard, fast, and fast-plus modes. The ADS1282HIPWR uses an SPI-compatible serial interface. System designers must ensure the host microcontroller supports the corresponding interface before selecting either device.
The ADS1219IPWR operates from a single analog and digital supply in the range of 2.7 V to 5.5 V. The ADS1282HIPWR requires a 5 V analog supply (AVDD) and a separate digital supply (DVDD) in the range of 1.8 V to 3.3 V. Power supply design must account for these differences.
The ADS1282HIPWR is specifically designed for seismic and energy exploration applications, offering 31-bit resolution, low noise, and data rates up to 4 kSPS. The ADS1219IPWR, with 24-bit resolution and lower data rates, is better suited for general-purpose multi-channel industrial sensing rather than high-resolution seismic acquisition.
Both the ADS1219IPWR and ADS1282HIPWR are specified for the industrial temperature range of -40°C to +125°C, as documented in their respective manufacturer datasheets. This allows both parts to be used in similar industrial environments, though other electrical and package differences remain.