ADS1282HIPWR vs ADS1220IPWR

Esta comparação detalhada entre ADS1282HIPWR e ADS1220IPWR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1220IPWR and ADS1282HIPWR are not drop-in replacements for one another. They differ in resolution and architecture, package and pinout, supply and reference requirements, and target application class, so substituting one for the other requires full electrical and layout validation rather than a direct swap.

Different resolution and architecture Different package and pinout Different supply and reference requirements Different application class

Parts at a glance

Part B

ADS1220IPWR

Texas Instruments

Lifecycle
Active
Stock
6260 PCS
Package
TSSOP-16
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1220IPWR ADS1282HIPWR Why it matters
Resolution (bits) 24 31 Higher resolution enables detection of smaller signal changes, which is critical for precision measurement and seismic/energy-exploration applications.
Number of input channels 4 (2 differential / 4 single-ended) 2 (1 differential) Channel count determines how many sensors can be interfaced; the ADS1220 supports more inputs while the ADS1282 is a single-channel high-resolution converter.
Maximum sample rate 2 kSPS 4 kSPS Sample rate sets the bandwidth of signals that can be captured; the ADS1282 offers higher throughput for faster-changing signals.
PGA gain range 1 to 128 V/V 1 to 64 V/V Programmable gain amplifies small sensor signals before conversion; a wider gain range allows the ADS1220 to resolve lower-amplitude inputs.
Supply voltage 2.7 V to 5.5 V (analog and digital) 5 V analog, 1.8 V to 3.3 V digital Supply requirements affect system power design and compatibility; the ADS1220 is more flexible for low-voltage systems while the ADS1282 needs a 5 V analog rail.
Interface SPI SPI Both use SPI, so the host microcontroller interface is compatible, easing board-level redesign between the two parts.
Package TSSOP-16 TSSOP-28 Different package footprints and pin counts mean the two parts are not drop-in replacements and require PCB layout changes.
Operating temperature range -40 °C to +125 °C -40 °C to +85 °C The wider temperature range of the ADS1220 suits harsher environments, while the ADS1282 is limited to standard industrial conditions.
Typical application focus Low-power sensor and temperature/pressure measurement High-resolution seismic and energy exploration The intended application domain indicates whether the part meets system-level performance and power targets for a given design.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1282HIPWR ADS1220IPWR
Part Status Active Active
Number of Bits 31 24
Sampling Rate (Per Second) 4k -
Number of Inputs 2 2, 4
Input Type Differential Differential, Single Ended
Data Interface SPI SPI
Configuration ADC MUX-PGA-ADC
Number of A / D Converters 1 -
Architecture Sigma-Delta Sigma-Delta
Reference Type External External, Internal, Supply
Voltage - Supply, Analog 5V 2.3V ~ 5.5V, ±2.5
Voltage - Supply, Digital 1.65V ~ 3.6V 2.3V ~ 5.5V
Features PGA PGA, Temperature Sensor
Operating Temperature -40°C ~ 85°C -40°C ~ 125°C
Mounting Type Surface Mount -
Base Product Number ADS1282 -
Sampling Rate(Per Second) - 2k
Number of A/D Converters - 1

Frequently asked questions

What are the primary differences between the ADS1220IPWR and ADS1282HIPWR?

The ADS1220IPWR is a 24-bit, 4-channel, 2-kSPS delta-sigma ADC with an integrated PGA and SPI interface in a TSSOP-16 package. The ADS1282HIPWR is a 31-bit, 2-channel, 4-kSPS delta-sigma ADC with an integrated PGA and SPI interface in a TSSOP-28 package, designed for high-resolution seismic and energy exploration applications.

Do the ADS1220IPWR and ADS1282HIPWR have the same pin count and package?

No. The ADS1220IPWR is supplied in a 16-pin TSSOP (PW) package, while the ADS1282HIPWR is supplied in a 28-pin TSSOP (PW) package. They are not pin-to-pin compatible and require different PCB land patterns.

What are the resolution and data rate specifications of each device?

The ADS1220IPWR provides 24-bit resolution with programmable data rates up to 2 kSPS. The ADS1282HIPWR provides 31-bit resolution with programmable data rates up to 4 kSPS.

How do the input channel configurations compare?

The ADS1220IPWR offers 4 single-ended or 2 differential input channels with an integrated PGA. The ADS1282HIPWR offers 2 differential input channels with an integrated PGA.

Are the supply voltage requirements of the ADS1220IPWR and ADS1282HIPWR the same?

No. The ADS1220IPWR operates from an analog supply of 2.3 V to 5.5 V and a digital supply of 2.3 V to 5.5 V. The ADS1282HIPWR operates from an analog supply of 4.75 V to 5.25 V and a digital supply of 1.65 V to 3.6 V, so the supply rails and decoupling requirements differ.

Can the ADS1220IPWR be used as a drop-in replacement for the ADS1282HIPWR?

No. The two devices differ in package pin count, resolution, channel count, maximum data rate, and supply voltage ranges. A direct drop-in replacement is not possible; any substitution requires a full design review against the respective datasheets.

Which device is better suited for high-resolution seismic or energy exploration measurements?

The ADS1282HIPWR is specified with 31-bit resolution and data rates up to 4 kSPS, making it the higher-resolution option of the two and the device intended for seismic and energy exploration signal chains. The ADS1220IPWR is a 24-bit, 2-kSPS device suited to lower-resolution, multi-channel sensor applications.