ADS1282HIPWR
Texas Instruments
- Lifecycle
- Active
- Stock
- 5203 PCS
- Series
- Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Esta comparação detalhada entre ADS1282HIPWR e ADS1271IBPWR fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.
Replacement verdict
The ADS1271IBPWR and ADS1282HIPWR are both 24-bit delta-sigma ADCs in TSSOP-28 packages, but they differ fundamentally in resolution architecture, input configuration, and target application class. The ADS1271IBPWR is a single-channel wide-bandwidth converter with a fixed data rate up to 105 kSPS, while the ADS1282HIPWR is a dual-channel high-resolution seismic-grade converter with integrated PGA and up to 4 kSPS output. Because the two devices are not pin-compatible in function and require different external circuitry, supply arrangements, and digital interfacing, the ADS1282HIPWR cannot be used as a direct drop-in substitute for the ADS1271IBPWR without a full redesign.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1271IBPWR | ADS1282HIPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 31 | Higher resolution enables finer signal detail and lower quantization noise, which is critical for precision measurement and seismic-grade applications. |
| Maximum Sample Rate (SPS) | 105k | 4k | Sample rate determines the bandwidth of signals that can be captured; the ADS1271 supports much wider bandwidth for high-speed data acquisition. |
| Number of Input Channels | 1 (differential) | 2 (differential, with mux) | Channel count affects how many signal sources can be measured; the ADS1282 offers an input multiplexer for two differential inputs. |
| Architecture | Delta-Sigma | Delta-Sigma | Both use delta-sigma conversion, but the ADS1282 is optimized for very high resolution at low speed while the ADS1271 targets wider bandwidth. |
| PGA / Gain Stage | No integrated PGA | Integrated PGA (1 to 64) | An integrated PGA allows direct connection of low-level sensors without external amplification, simplifying the signal chain. |
| Supply Voltage (Analog) | 5 V | 5 V (analog), 3.3 V (digital) | Supply requirements affect board-level power design and compatibility with surrounding logic and analog circuitry. |
| Interface | SPI (serial) | SPI (serial) | Both use SPI, but timing and register maps differ, so firmware must be adapted when substituting one for the other. |
| Package | TSSOP-16 (PW) | TSSOP-28 (PW) | Different package footprints and pin counts prevent direct drop-in replacement on an existing PCB layout. |
| Operating Temperature Range | -40°C to +105°C | -40°C to +85°C | The wider temperature range of the ADS1271 suits harsher environments, while the ADS1282 covers standard industrial conditions. |
| Typical Application Focus | Industrial measurement, vibration, data acquisition | Seismic, energy exploration, high-resolution sensor systems | Application focus indicates the intended noise/bandwidth trade-off and helps judge functional substitutability for a given design. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1282HIPWR | ADS1271IBPWR |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 31 | 24 |
| Sampling Rate (Per Second) | 4k | - |
| Number of Inputs | 2 | 1 |
| Input Type | Differential | Differential |
| Data Interface | SPI | SPI |
| Configuration | ADC | ADC |
| Number of A / D Converters | 1 | - |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 5V | 5V |
| Voltage - Supply, Digital | 1.65V ~ 3.6V | 1.65V ~ 3.6V |
| Features | PGA | - |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 105°C |
| Mounting Type | Surface Mount | - |
| Base Product Number | ADS1282 | - |
| Sampling Rate(Per Second) | - | 105k |
| Number of A/D Converters | - | 1 |
The ADS1271IBPWR is a 24-bit, single-channel delta-sigma ADC with a fixed data rate up to 105 kSPS and a passband flat to 0.455 × fDATA. The ADS1282HIPWR is a 31-bit, single-channel delta-sigma ADC with a programmable data rate up to 4 kSPS and an on-chip programmable gain amplifier (PGA) with gains of 1, 2, 4, 8, 16, 32, and 64. The ADS1282 also integrates a low-noise PGA and supports a wider analog supply range, making it suited to high-resolution seismic and energy exploration applications.
No. The ADS1271IBPWR is supplied in a 20-pin TSSOP (PW) package, while the ADS1282HIPWR is supplied in a 28-pin TSSOP (PW) package. The two devices have different pin counts and pin functions, so they are not drop-in replacements and require different PCB land patterns.
The ADS1271IBPWR provides 24-bit resolution with data rates up to 105 kSPS. The ADS1282HIPWR provides 31-bit resolution with a maximum data rate of 4 kSPS. The ADS1282 trades higher resolution and lower noise for a lower maximum output data rate, while the ADS1271 offers higher throughput at 24-bit resolution.
Yes. The ADS1282HIPWR integrates a programmable gain amplifier with selectable gains of 1, 2, 4, 8, 16, 32, and 64, allowing direct connection of low-level sensors. The ADS1271IBPWR does not include an integrated PGA; it provides a fixed-gain differential input suitable for higher-level signals.
The ADS1271IBPWR operates from a 5 V analog supply (AVDD) and a 1.8 V to 3.3 V digital supply (DVDD). The ADS1282HIPWR operates from a 5 V analog supply (AVDD) and a 1.8 V to 3.3 V digital supply (DVDD), and additionally requires an analog supply for its internal circuitry. Designers should confirm exact supply ranges against the respective manufacturer datasheets before finalizing the power tree.
The ADS1282HIPWR is specifically designed for seismic and energy exploration systems, offering 31-bit resolution, an integrated PGA, and low-noise performance at data rates up to 4 kSPS. The ADS1271IBPWR, with 24-bit resolution and up to 105 kSPS, is better suited to higher-speed industrial measurement and vibration applications where throughput is prioritized over maximum resolution.
Both devices provide a serial digital interface for output data, but the ADS1271IBPWR supports both SPI-compatible and frame-sync modes, while the ADS1282HIPWR uses an SPI-compatible interface with additional control registers for PGA and filter configuration. The interface protocols are similar but not identical, so firmware and host controller configuration must be adapted to each device.