ADS1259IPWR vs ADS1282IPW

Esta comparação detalhada entre ADS1259IPWR e ADS1282IPW fornece informações valiosas sobre suas especificações e principais características. Abordamos fatores importantes em detalhes, incluindo conformidade com RoHS, status REACH, série, estilo de montagem, tipo de encapsulamento e outras características relevantes. Apresentar as diferenças lado a lado simplifica a seleção de componentes, facilitando a escolha da melhor opção para sua aplicação específica.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1282IPW and ADS1259IPWR are both high-resolution delta-sigma ADCs, but they differ fundamentally in resolution, input architecture, package footprint, and interface configuration, so neither device can be substituted for the other without a full redesign and revalidation of the signal chain.

Different resolution Different input architecture Different package footprint Different interface configuration

Parts at a glance

Part A

ADS1259IPWR

Texas Instruments

Lifecycle
Active
Stock
6414 PCS
Package
TSSOP-20
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)
Part B

ADS1282IPW

Texas Instruments

Lifecycle
Active
Stock
4636 PCS
Package
TSSOP-28
Series
Acquisição de dados - Analogo para Convertedores Digitais (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1282IPW ADS1259IPWR Why it matters
Resolution (bits) 31 24 Higher resolution enables finer measurement of small signal changes, which is critical for precision sensing applications.
Architecture Delta-Sigma (2nd order) Delta-Sigma The modulator architecture affects noise shaping, linearity, and suitability for different signal bandwidths.
Sample Rate (max) 4 kSPS 14.4 kSPS Maximum sample rate determines the highest signal bandwidth the ADC can capture without aliasing.
Number of Input Channels 2 (differential) 1 (differential) Channel count determines how many independent signals can be measured without external multiplexing.
Input Type Differential Differential Differential inputs reject common-mode noise, improving accuracy in electrically noisy environments.
Supply Voltage 2.7 V to 5.25 V (analog), 1.8 V to 3.6 V (digital) 4.75 V to 5.25 V (analog), 2.7 V to 5.25 V (digital) Supply voltage compatibility determines whether the part can drop into an existing power rail design.
Interface SPI SPI A matching serial interface simplifies firmware reuse and board-level integration.
Package / Mounting TSSOP-28 (Surface Mount) TSSOP-20 (Surface Mount) Package footprint and pin count affect PCB layout and whether a direct board swap is possible.
Operating Temperature Range -40°C to +85°C -40°C to +105°C The temperature range must cover the target application environment for reliable operation.
Internal PGA Yes No An integrated PGA allows direct connection of low-level sensors without external amplification.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1259IPWR ADS1282IPW
Part Status Active Active
Number of Bits 24 31
Sampling Rate(Per Second) 14k 4k
Number of Inputs 1 1
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 2.7V ~ 5.25V 1.65V ~ 3.6V
Features PGA PGA
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C

Frequently asked questions

What are the primary functional differences between the ADS1282IPW and ADS1259IPWR?

The ADS1282IPW is a 31-bit delta-sigma ADC with an integrated programmable gain amplifier (PGA) and two-channel input multiplexer, designed primarily for seismic and energy exploration applications. The ADS1259IPWR is a 24-bit delta-sigma ADC with a single-channel input and integrated PGA, optimized for high-resolution industrial measurement. The ADS1282 offers higher nominal resolution (31-bit) and dual input channels, while the ADS1259 provides 24-bit resolution in a single-channel configuration.

Do the ADS1282IPW and ADS1259IPWR share the same package and pinout?

No. The ADS1282IPW is supplied in a 28-pin TSSOP (PW) package, while the ADS1259IPWR is supplied in a 20-pin TSSOP (PW) package. The different pin counts and pin functions mean the two devices are not pin-compatible and cannot be dropped into the same PCB land pattern without redesign.

What are the maximum output data rates of the ADS1282IPW and ADS1259IPWR?

The ADS1282IPW supports output data rates up to 4 kSPS in its high-resolution mode. The ADS1259IPWR supports output data rates up to 18.5 kSPS in its fastest configuration. The ADS1259 therefore offers a higher maximum throughput, while the ADS1282 prioritizes resolution and low-noise performance at lower rates.

How do the input configurations of the ADS1282IPW and ADS1259IPWR differ?

The ADS1282IPW provides a two-channel differential input multiplexer, allowing selection between two differential input pairs. The ADS1259IPWR provides a single differential input channel. Designs requiring multiple sensor inputs may favor the ADS1282, while single-channel high-resolution measurement suits the ADS1259.

Are the ADS1282IPW and ADS1259IPWR interchangeable in an existing design?

No. Differences in package pin count (28-pin vs 20-pin TSSOP), resolution (31-bit vs 24-bit), input channel count (two vs one), and maximum data rate (4 kSPS vs 18.5 kSPS) prevent direct interchangeability. Any substitution requires schematic, layout, and firmware validation against the respective manufacturer datasheets.

What are the typical target applications for the ADS1282IPW versus the ADS1259IPWR?

The ADS1282IPW is typically used in seismic data acquisition, energy exploration, and precision industrial instrumentation requiring dual-channel high-resolution conversion. The ADS1259IPWR is typically used in single-channel high-resolution industrial measurement, process control, and sensor interface applications where a higher output data rate is beneficial.

Do both devices operate from the same analog supply voltage?

Both the ADS1282IPW and ADS1259IPWR operate from a 5 V analog supply (AVDD) with a separate digital supply (DVDD) in the 1.8 V to 3.3 V range, per their respective manufacturer datasheets. Designers should confirm exact supply tolerances and sequencing requirements in the official datasheets before finalizing a design.